Hannoband®-BSB BG1

The fire protection tape - tight and fire-resistant

Hannoband®-BSB BG1

Product description

This special fire protection tape is flame-retardant in accordance with DIN 4102 T1 and can be used up to fire resistance class EI 120. Can also be used for directly weathered joints. For interior fire doors and partition walls, for fire-resistant windows and for forming joints between masonry elements to ensure fire resistance.

Tender texts

To the VKF fire protection register

Properties

  • joint sealing tape with acrylate dispersion impregnation specially formulated for fire protection
  • stress group BG1 DIN 18542:2009
  • for driving rain-proof expansion and connection joints in window construction ≥ 600 Pa
  • Joint permeabilityat ≤ 1.0 m³/(h∙m∙(daPa)2/3)
  • sd value ≤ 0.5 m
  • Colour: Light grey

Test certificates

  • DIN EN 1366-4 Fire resistance duration up to 120 minutes with double installation between masonry and masonry (see test report)
  • DIN EN 1366-4 Fire resistance duration 60 minutes with double installation between masonry and timber frame (see test report)
  • System test block frame 59 mm wide: 12 mm joint filled with Hannoband®-BSB BG1 fire protection tape 20/7-12. Remaining joint filled with Hanno® fire protection foam. Fire resistance duration: 36 minutes
  • System test Block frame 60 mm wide: 5-9 mm joint filled with 2 x Hannoband®-BSB BG1 fire protection tape 15/5-9. Fire resistance duration: EI 60 in accordance with DIN EN 13501-2
  • Building material class B1 flame retardant according to DIN 4102
  • Eurofins Product Testing A/S
    Measurement of emissions
  • GEV - Gemeinschaft Emissionskontrollierte Verlegewerkstoffe, Klebstoffe und Bauprodukte e.V. - Certification with EMICODE® EC1PLUS