Product description
If you want to have perfectly sealed construction joints in the long term, choose Hannoband®-BG1: Even after an outdoor weathering test over more than 15 years in the joint, Hannoband® still clearly exceeds the requirements for driving rain tightness, airtightness and weather resistance of DIN 18542.
Hannoband®-BG1 XL
Hannoband®-BG1 is also available as Hannoband®-BG1 XL in longer roll lengths especially for window construction. This helps to avoid waste and facilitates quick installation.
Hannoband®-BG1-M
Hannoband®-BG1-M Hanno membrane technology is used for the particularly demanding larger joint widthn.
Properties
- for highly stressed primary and cross joints
- all relevant test certificates
- Resistant to long-term weathering
- European Technical Approval ETA 06/0083
- complies with DIN 18542:2009, stress group 1
- Building material class B1 DIN 4102
- Thermal conductivity λ=0.0412 W/mK
- driving rain tight ≥ 600 Pa
- Joint sound insulation valueRS,W ≥ 60 dB (with double installation)
- Temperature resistance from -30°C to +100°C, short-term up to +130°C
- open to diffusion
- Compatible with paint
MPA Bau Hannover - Materials Testing Institute for the Building Industry Hannover
- Testing according to DIN 18542:2009, stress group 1
- External monitoring contract
- Determination of thermal conductivity
MPA-Hannover - Materials Testing Institute for Materials and Production Technology
- Assessment after practical outdoor weathering over a period of 15 years
European Organisation for Technical Approvals
- European Technical Approval ETA 06/0083 (CE certificate)
ift Rosenheim
- Proof of joint sound insulation
Kiwa N.V., NL-2280 AB Rijswijk
- Komo product certificate
Socotec
- Certification according to NFP85-570 and NFP85-571
Eurofins Product Testing A/S
- Measurement of emissions
GEV - Association of Emission Controlled Installation Materials
- Certification with EMICODE® EC1PLUS
eco-bau
- Certification "basis"
DIBT - German Institute for Building Technology, Berlin
- General building authority approval
- Building material class B1 according to DIN 4102
ATI, Architectural Testing, Inc., York, Pennsylvania
- Hurricane test according to Miami Dade in accordance with ASTM E284, 330, 331